Code A |
4.2 - DC Supply Voltage Test (6-16 V DC) |
|
4.3.1.1 - Long Term Overvoltage (18 V DC) |
|
4.3.1.2 - Jump Start Transient (26 V DC) |
|
4.3.2 - Transient Overvoltage x5 (18 V DC) |
|
4.5 - Slow Decrease and Increase of Supply Voltage (14 V DC) |
|
4.6.1.1 - Short Voltage Drop (4,5-6 V DC) |
|
4.6.2 - Reset Behavior at Voltage Drop (6 V DC) |
|
4.6.3 (Level I) - Starting Profile x10 (8-12 V DC) |
|
4.6.3 (Level II) - Starting Profile x10 (4,5-12 V DC) |
|
4.6.3 (Level III) - Starting Profile x10 (3-12 V DC) |
|
4.6.3 (Level IV) - Starting Profile x10 (6-12 V DC) |
|
4.7 (Test Case 1) - Reversed Voltage (6 to -4 V DC) |
|
4.7 (Test Case 2) - Reversed Voltage (0 to -14 V DC) |
Code B |
4.2 - DC Supply Voltage Test (8-16 V DC) |
4.3.1.1 - Long Term Overvoltage (18 V DC) |
4.3.1.2 - Jump Start Transient (26 V DC) |
4.3.2 - Transient Overvoltage x5 (18 V DC) |
4.5 - Slow Decrease and Increase of Supply Voltage (14 V DC) |
4.6.1.1 - Short Voltage Drop (4,5-8 V DC) |
4.6.2 - Reset Behavior at Voltage Drop (8 V DC) |
4.6.3 (Level I) - Starting Profile x10 (8-12 V DC) |
4.6.3 (Level II) - Starting Profile x10 (4,5-12 V DC) |
4.6.3 (Level III) - Starting Profile x10 (3-12 V DC) |
4.6.3 (Level IV) - Starting Profile x10 (6-12 V DC) |
4.7 (Test Case 1) - Reversed Voltage (8 to -4 V DC) |
4.7 (Test Case 2) - Reversed Voltage (0 to -14 V DC) |
Code C |
4.2 - DC Supply Voltage Test (9-16 V DC) |
4.3.1.1 - Long Term Overvoltage (18 V DC) |
4.3.1.2 - Jump Start Transient (26 V DC) |
4.3.2 - Transient Overvoltage x5 (18 V DC) |
4.5 - Slow Decrease and Increase of Supply Voltage (14 V DC) |
4.6.1.1 - Short Voltage Drop (4,5-9 V DC) |
4.6.2 - Reset Behavior at Voltage Drop (9 V DC) |
4.6.3 (Level I) - Starting Profile x10 (8-12 V DC) |
4.6.3 (Level II) - Starting Profile x10 (4,5-12 V DC) |
4.6.3 (Level III) - Starting Profile x10 (3-12 V DC) |
4.6.3 (Level IV) - Starting Profile x10 (6-12 V DC) |
4.7 (Test Case 1) - Reversed Voltage (9 to -4 V DC) |
4.7 (Test Case 2) - Reversed Voltage (0 to -14 V DC) |
Code D |
4.2 - DC Supply Voltage Test (10,5-16 V DC) |
4.3.1.1 - Long Term Overvoltage (18 V DC) |
4.3.1.2 - Jump Start Transient (26 V DC) |
4.3.2 - Transient Overvoltage x5 (18 V DC) |
4.5 - Slow Decrease and Increase of Supply Voltage (14 V DC) |
4.6.1.1 - Short Voltage Drop (4,5-10,5 V DC) |
4.6.2 - Reset Behavior at Voltage Drop (10,5 V DC) |
4.6.3 (Level I) - Starting Profile x10 (8-12 V DC) |
4.6.3 (Level II) - Starting Profile x10 (4,5-12 V DC) |
4.6.3 (Level III) - Starting Profile x10 (3-12 V DC) |
4.6.3 (Level IV) - Starting Profile x10 (6-12 V DC) |
4.7 (Test Case 1) - Reversed Voltage (10,5 to -4 V DC) |
4.7 (Test Case 2) - Reversed Voltage (0 to -14 V DC) |
Code E |
4.2 - DC Supply Voltage Test (10-32 V DC) |
4.3.1 - Long Term Overvoltage (36 V DC) |
4.3.2 - Transient Overvoltage x5 (36 V DC) |
4.5 - Slow Decrease and Increase of Supply Voltage (28 V DC) |
4.6.1.1 - Short Voltage Drop (9-10 V DC) |
4.6.2 - Reset Behavior at Voltage Drop (10 V DC) |
4.6.3 (Level I) - Starting Profile x10 (10-24 V DC) |
4.6.3 (Level II) - Starting Profile x10 (8-24 V DC) |
4.6.3 (Level III) - Starting Profile x10 (6-24 V DC) |
4.7 (Test Case 2) - Reversed Voltage (0 to -26 V DC) |
Code F |
4.2 - DC Supply Voltage Test (16-32 V DC) |
4.3.1 - Long Term Overvoltage (36 V DC) |
4.3.2 - Transient Overvoltage x5 (36 V DC) |
4.5 - Slow Decrease and Increase of Supply Voltage (28 V DC) |
4.6.1.1 - Short Voltage Drop (9-16 V DC) |
4.6.2 - Reset Behavior at Voltage Drop (16 V DC) |
4.6.3 (Level I) - Starting Profile x10 (10-24 V DC) |
4.6.3 (Level II) - Starting Profile x10 (8-24 V DC) |
4.6.3 (Level III) - Starting Profile x10 (6-24 V DC) |
4.7 (Test Case 2) - Reversed Voltage (0 to -26 V DC) |
Code G |
4.2 - DC Supply Voltage Test (22-32 V DC) |
4.3.1 - Long Term Overvoltage (36 V DC) |
4.3.2 - Transient Overvoltage x5 (36 V DC) |
4.5 - Slow Decrease and Increase of Supply Voltage (28 V DC) |
4.6.1.1 - Short Voltage Drop (9-22 V DC) |
4.6.2 - Reset Behavior at Voltage Drop (22 V DC) |
4.6.3 (Level I) - Starting Profile x10 (10-24 V DC) |
4.6.3 (Level II) - Starting Profile x10 (8-24 V DC) |
4.6.3 (Level III) - Starting Profile x10 (6-24 V DC) |
4.7 (Test Case 2) - Reversed Voltage (0 to -26 V DC) |
Code H |
4.2 - DC Supply Voltage Test (18-32 V DC) |
4.3.1 - Long Term Overvoltage (36 V DC) |
4.3.2 - Transient Overvoltage x5 (36 V DC) |
4.5 - Slow Decrease and Increase of Supply Voltage (28 V DC) |
4.6.1.1 - Short Voltage Drop (9-18 V DC) |
4.6.2 - Reset Behavior at Voltage Drop (18 V DC) |
4.6.3 (Level I) - Starting Profile x10 (10-24 V DC) |
4.6.3 (Level II) - Starting Profile x10 (8-24 V DC) |
4.6.3 (Level III) - Starting Profile x10 (6-24 V DC) |
4.7 (Test Case 2) - Reversed Voltage (0 to -26 V DC) |