Includes these tests from General Motors GMW3172 H (July 2010):

8.2.1 Jump Start
8.2.2 Reverse Polarity
8.2.3 Overvoltage (with overvoltage protection)
8.2.4 State Change Waveform Characterization
9.2.1 Parasitic Current
9.2.2 Power Supply Interruptions, 12V, Code A
Power Supply Interruptions, 12V, Code B
Power Supply Interruptions, 12V, Code C & D
9.2.3 Battery Voltage Dropout, 12VDC, Code A
Battery Voltage Dropout, 12VDC, Code B
Battery Voltage Dropout, 12VDC, Code C & D
Battery Voltage Dropout, 12VDC, Code E
Battery Voltage Dropout, 12VDC, Code F
9.2.4 Sinusoidal Superimposed Voltage, 12VDC
9.2.5 Pulse Superimposed Voltage, 12VDC, U(p) only
9.2.7   Continuous Short Circuit to Battery and to Ground, 12VDC, Code A
Continuous Short Circuit to Battery and to Ground, 12VDC, Code B
Continuous Short Circuit to Battery and to Ground, 12VDC, Code C
Continuous Short Circuit to Battery and to Ground, 12VDC, Code D
Continuous Short Circuit to Battery and to Ground, 12VDC, Code E
Continuous Short Circuit to Battery and to Ground, 12VDC, Code F
9.2.8 Ground Interconnect Short to Battery, 12VDC, Code A, B, C, E, F
Ground Interconnect Short to Battery, 12VDC, Code D
9.2.17 Crank Pulse Capability and Durability, Severity I, Functional, 12VDC
Crank Pulse Capability and Durability, Severity I, Durability, 12VDC
Crank Pulse Capability and Durability, Severity II, Ua=2.5V, Functional, 12VDC
Crank Pulse Capability and Durability, Severity II, Ua=2.5V, Durability, 12VDC
Crank Pulse Capability and Durability, Severity II, Ua=3V, Functional, 12VDC
Crank Pulse Capability and Durability, Severity II, Ua=3V, Durability, 12VDC
Crank Pulse Capability and Durability, Severity III, Ua=2.5V, Functional, 12VDC
Crank Pulse Capability and Durability, Severity III, Ua=2.5V, Durability, 12VDC
Crank Pulse Capability and Durability, Severity III, Ua=3V, Functional, 12VDC
Crank Pulse Capability and Durability, Severity III, Ua=3V, Durability, 12VDC
Crank Pulse Capability and Durability, Severity III, Ua=4V, Functional, 12VDC
Crank Pulse Capability and Durability, Severity III, Ua=4V, Durability, 12VDC
Crank Pulse Capability and Durability, Severity IV, Ua=2.5V, Functional, 12VDC
Crank Pulse Capability and Durability, Severity IV, Ua=2.5V, Durability, 12VDC
Crank Pulse Capability and Durability, Severity IV, Ua=3V, Functional, 12VDC
Crank Pulse Capability and Durability, Severity IV, Ua=3V, Durability, 12VDC
Crank Pulse Capability and Durability, Severity III, Ua=4V, Functional, 12VDC
Crank Pulse Capability and Durability, Waveform 1, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 1, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 1, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 1, Functional, 12VDC
Crank Pulse Capability and Durability, Waveform 1, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 2, Functional, 12VDC
Crank Pulse Capability and Durability, Waveform 2, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 3, Functional, 12VDC
Crank Pulse Capability and Durability, Waveform 3, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 4, Functional, 12VDC
Crank Pulse Capability and Durability, Waveform 4, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 5, Functional, 12VDC
Crank Pulse Capability and Durability, Waveform 5, Durability, 12VDC
Crank Pulse Capability and Durability, Waveform 6, Functional, 12VDC
Crank Pulse Capability and Durability, Waveform 6, Durability, 12VDC
9.3.1 Vibration with Thermal Cycling, 12VDC
9.3.2 Post Thermal Fatigue Vibration, 12VDC
9.3.3 Mechanical Shock - Pothole, 12VDC
9.3.5 Mechanical Shock - Closure Slam, 12VDC
9.3.9 Connector Installation Abuse - Side Force, 12VDC
9.3.10 Connector Installation Abuse - Foot Load, 12VDC
9.4.1 High Temperature Degradation, 12VDC
9.4.3 Power Temperature Cycle, 12VDC
9.4.4 Thermal Shock Water Splash, 12VDC
9.4.5 Humid Heat Cylic, 12VDC
9.4.6 Humid Heat Constant, 12VDC
9.4.8 Salt Spray, IP Water Code 3 or 6K, wet side of door interiior, 12VDC
Salt Spray, IP Water Code 6K or 8 or 9K, non interior component without direct exposure to salt spray,12VDC
Salt Spray, IP Water Code 6K or 8 or 9K, non interior component  with direct exposure to salt spray, 12VDC
9.5.3 Seal, 12VDC
9.5.4 Water Freeze, 12VDC
9.5.5 Sugar Water Function Impairment, 12VDC