Includes these tests from General Motors GMW3172 I:

<
  12V DC Power Supply
  24V DC Power Supply
8.2.1 Jump Start 26.5V
  Jump Start 26V
8.2.2 Reverse Polarity
8.2.3 Overvoltage With Protection
  Overvoltage Without Protection
8.2.4 State Change Waveform Characterization
8.4.2 Low Temperature Wakeup Code A-D Component
  Low Temperature Wakeup Code E-H Component
9.2.1 Parasitic Current
9.2.2 Power Supply Interruptions Code A Component
  Power Supply Interruptions Code B Component
  Power Supply Interruption Code C Component
  Power Supply Interruption Code D Component
  Power Supply Interruptions Code E Component
  Power Supply Interruptions Code F Component
  Power Supply Interruption Code G Component
  Power Supply Interruption Code H Component
9.2.3 Battery Voltage Dropout Code A Component
Battery Voltage Dropout Code B Component
Battery Voltage Dropout Code C Component
Battery Voltage Dropout Code D Component
9.2.4 Sinusoidal Superimposed Voltage, 12VDC
  Sinusoidal Superimposed Voltage, 24VDC
9.2.5 Pulse Superimposed Voltage U(p) only
9.2.6   Intermitent Short Circuit to Battery and to Ground Code A Component
    Intermitent Short Circuit to Battery and to Ground Code B Component
    Intermitent Short Circuit to Battery and to Ground Code C Component
    Intermitent Short Circuit to Battery and to Ground Code D Component
    Intermitent Short Circuit to Battery and to Ground Code E Component
    Intermitent Short Circuit to Battery and to Ground Code F Component
    Intermitent Short Circuit to Battery and to Ground Code G Component
    Intermitent Short Circuit to Battery and to Ground Code B Component
9.2.7   Continuous Short Circuit to Battery and to Ground Code A Component
    Continuous Short Circuit to Battery and to Ground Code B Component
    Continuous Short Circuit to Battery and to Ground Code C Component
    Continuous Short Circuit to Battery and to Ground Code D Component
    Continuous Short Circuit to Battery and to Ground Code E Component
    Continuous Short Circuit to Battery and to Ground Code F Component
    Continuous Short Circuit to Battery and to Ground Code G Component
    Continuous Short Circuit to Battery and to Ground Code H Component
9.2.8 Multiple Power and Multiple Ground Short Circuits Including Pass Through Code A Component
    Multiple Power and Multiple Ground Short Circuits Including Pass Through Code B Component
    Multiple Power and Multiple Ground Short Circuits Including Pass Through Code C Component
    Multiple Power and Multiple Ground Short Circuits Including Pass Through Code D Component
    Multiple Power and Multiple Ground Short Circuits Including Pass Through Code E Component
    Multiple Power and Multiple Ground Short Circuits Including Pass Through Code F Component
    Multiple Power and Multiple Ground Short Circuits Including Pass Through Code G Component
    Multiple Power and Multiple Ground Short Circuits Including Pass Through Code H Component
9.2.11 Ground Offset Code A Component
    Ground Offset Code B Component
    Ground Offset Code C Component
    Ground Offset Code D Component
    Ground Offset Code E Component
    Ground Offset Code F Component
    Ground Offset Code G Component
    Ground Offset Code H Component
9.2.12 Power Offset Code A Component
    Power Offset Code B Component
    Power Offset Code C Component
    Power Offset Code D Component
    Power Offset Code E Component
    Power Offset Code F Component
    Power Offset Code G Component
    Power Offset Code H Component
9.2.13 Discrete Digital Input Threshold Voltage (Us) Code A Component
    Discrete Digital Input Threshold Voltage (Us) Code B Component
    Discrete Digital Input Threshold Voltage (Us) Code C Component
    Discrete Digital Input Threshold Voltage (Us) Code D Component
    Discrete Digital Input Threshold Voltage (Us) Code E Component
    Discrete Digital Input Threshold Voltage (Us) Code F Component
    Discrete Digital Input Threshold Voltage (Us) Code G Component
    Discrete Digital Input Threshold Voltage (Us) Code H Component
9.2.17 Crank Pulse Capability and Durability, Pulse 4, Severity I, Ua=2.5V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity I, Ua=2.5V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity II, Ua=2.5V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity II, Ua=2.5V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity II, Ua=3V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity II, Ua=3V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity III, Ua=2.5V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity III, Ua=2.5V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity III, Ua=3V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity III, Ua=3V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity III, Ua=4V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity III, Ua=4V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=2.5V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=2.5V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=3V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=3V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=4V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=4V Functional Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=5V Durability Test
  Crank Pulse Capability and Durability, Pulse 4, Severity IV, Ua=5V Functional Test
  Crank Pulse Capability and Durability, Waveform 1, Durability Test
  Crank Pulse Capability and Durability, Waveform 1, Functional Test
  Crank Pulse Capability and Durability, Waveform 2, Durability Test
  Crank Pulse Capability and Durability, Waveform 2, Functional Test
  Crank Pulse Capability and Durability, Waveform 3, Durability Test
  Crank Pulse Capability and Durability, Waveform 3, Functional Test
9.2.18 Switched Battery Lines
9.2.19 Battery Line Transients
9.3.1 Vibration with Thermal Cycling
9.3.2 Mechanical Shock - Pothole
9.3.3 Mechanical Shock - Collision
9.3.4 Mechanical Shock - Closure Slam
9.3.8 Connector Installation Abuse - Side Force
9.3.9 Connector Installation Abuse - Foot Load
9.4.1 High Temperature Degradation, 2000 h, Code A
  High Temperature Degradation, 2000 h, Code B
  High Temperature Degradation, 2000 h, Code C
  High Temperature Degradation, 2000 h, Code D
  High Temperature Degradation, 2000 h, Code E
  High Temperature Degradation, 2000 h, Code F
  High Temperature Degradation, 2000 h, Code G
  High Temperature Degradation, 2000 h, Code H
  High Temperature Degradation, 500 h, Code A
  High Temperature Degradation, 500 h, Code B
  High Temperature Degradation, 500 h, Code C
  High Temperature Degradation, 500 h, Code D
  High Temperature Degradation, 500 h, Code E
  High Temperature Degradation, 500 h, Code F
  High Temperature Degradation, 500 h, Code G
  High Temperature Degradation, 500 h, Code H
9.4.3 Power Temperature Cycle, Code A
  Power Temperature Cycle, Code B
  Power Temperature Cycle, Code C
  Power Temperature Cycle, Code D
  Power Temperature Cycle, Code E
  Power Temperature Cycle, Code F
  Power Temperature Cycle, Code G
  Power Temperature Cycle, Code H
9.4.5 Humid Heat Cylic
9.4.6 Humid Heat Constant
9.4.8 Salt Spray, IP Water Code 3 or 6K
 /td> Salt Spray, IP Water Code 6K or 8K or 9K
  Salt Spray, IP Water Code 6K or 8 or 9K, non interior component without direct exposure to salt spray,12VDC
  Salt Spray, IP Water Code 6K or 8 or 9K
9.5.3 Seal
9.5.5 Water Freeze
9.5.6 Sugar Water Function Impairment