9130

DC-250kHz Switch-Mode Amplifier Power System

9130

10 kW, up to 180A continuous

Key Performance Capabilities:
  • Bandwidth: DC to 250 kHz
  • Minimum Drop/Rise Time: 7µs
  • Slew Rate: Up to 150 V/µs
  • Max Voltage: 0 to 200 Vp
  • Max Current: Up to 140 Ap / 180A RMS
  • Distortion: <0.1% at 1 kHz below clip
  • Max Long-Term Power: 10 kW*
  • Typical Output Ripple: 0.6V RMS
  • Power Factor: Typically 95% or greater

*At mains power below 208VAC, 30A maximum power will be reduced.

SKU: N/A Categories: ,
OVERVIEW

The 9130 is a powerful and flexible amplifier power system when the environment is difficult or existing AC Mains options are limited. This cabinet-based model, comprised of two 9115 units, can be powered from a variety of three-phase voltages from 200VAC to 415VAC*. It is power-efficient, with a typical efficiency over 90% at full power.

This combination of features makes the 9130 an ideal solution for a wide range of high-current, low-voltage applications that require both wide bandwidth and the ability to drive reactive or widely varying load impedances.

  • Stable when driving highly capacitive loads
  • Four-quadrant operation
  • User-selectable gain
  • User-selectable current limit to protect fragile DUTs or where specified in the Standard
  • DC enabled or DC blocked and DC Servo (for driving transformer-coupled loads or coils)
  • Balanced and/or unbalanced input
  • Operate as a voltage-controlled voltage source or voltage-controlled current source
  • Variable output impedance from 0 to 1 ohm (Voltage mode)

* Three-phase voltages above 240VAC will require a 5-wire service.

OUTPUT CHART

Output

  CONTINUOUS OUTPUT CURRENT
  9105 9110 9115 9130 9145 9160 9175 9190
13.5 VDC 35A 60A 90A 180A 270A 360A 450A 540A
24 VDC 35A 60A 90A 180A 270A 360A 450A 540A
48 VDC 34A 60A 90A 180A 270A 360A 450A 540A
30 VAC 35A 70A 90A 180A 270A 360A 450A 540A
60 VAC 35A 70A 80A 160A 240A 320A 400A 480A
120 VAC 35A 37A 37A 74A 100A 137A 174A 200A

Note: Performance data is for a purely resistive load; performance will be improved into loads that are partially or completely reactive.

 
PERFORMANCE

 

     
SPECIFICATIONS

Performance Specifications

  • Operating Modes: AC, DC, and AC + DC
  • Frequency, AC Mode Output (-3 dB): DC – 250 kHz
  • Max Voltage Ranges (no load),
    • AC: 0 – 140 VRMS
    • AC + DC: 0 – ±200 VP
  • Maximum Continuous Output Current: 180RMS AC or DC
  • Power: 10 kW
  • Supply Voltage: Universal power supply with PFC, three-phase, 200V to 415VAC* ±10%, 30A, 50/60 Hz
  • Load Regulation (ref to full scale): <0.05%, DC to 100 Hz; <0.1%, 10 Hz to 10 kHz
  • Line Regulation (full scale): 100V to 250V ACRMS
  • Harmonic Distortion,
    • 80 kHz, Low-passed: Less than 0.3% from 10 Hz to 30 kHz; 0.5% up to 50 kHz
    • 30 kHz, Low-passed: Less than 0.1% from 10 Hz to 50 kHz
  • Quiescent Power,
    • Standby: 110W
    • Run: 510W
  • DC Offset: <2 mV
  • Distortion: <1.0%
  • THD: .02% at 1kHz
  • Voltage Slew Rate, 8Ω: 150V per µs
  • Voltage Ripple: 250mV @ 250kHz
  • Efficiency: 85%, typical
  • Power Factor: .98, typical
  • Source Impedance: 5 mΩ + 6 µH
  • Cooling: Internal forced-air fans
  • Protection: Over/under voltage, over current, over temperature
  • Input, Signal In: BNC connector (unbalanced)
  • Output: High-current barrier strip

* Three-phase voltages above 240VAC will require a 5-wire service.

 

Operating Environment

  • Temperature: 5°C to 50°C (41°F to 122°F);
    Maximum output power de-rated above 30°C (86°F)
  • Humidity: Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C
  • Altitude: 3000 m Maximum
  • Environment: Indoor Use Only, Pollution degree 2
  • Equipment Class: Group 1 Class A
  • Transient Overvoltage: Overvoltage Category II
  • Dimensions (HxWxD): 35.05 x 22.56 x 31.56 in. (89.03 x 57.3 x 80.16 cm)
  • Weight (Approx.): 222 lbs. (100.7 kg)
PHOTOS

Controls, Indicators and Connectors

DOCUMENTS / DOWNLOADS
9100 Series Data Sheet 9100 Series Manual 9100 Series Configuration Settings

 

You may also like…

EMC Test Systems
We provide comprehensive solutions for power quality, conducted immunity, and induced susceptibility testing for the EMC industry.

High-Voltage Test Systems
Our high-voltage ripple test systems provide unparalleled accuracy and efficiency in assessing EV component immunity to ripple voltages.

Low-Voltage Test Systems
We provide comprehensive, single-box solutions for low-voltage standards testing for automotive, aerospace, industrial, and telecom industries.


Standards Waveform Generator