Includes these tests from ISO 16750-2:

-->
4.1 Short Circuit Protection, 12VDC
  Short Circuit Protection, 24VDC
4.2 Direct Current Supply Voltage, 12VDC, Code A
Direct Current Supply Voltage, 12VDC, Code B
Direct Current Supply Voltage, 12VDC, Code C
Direct Current Supply Voltage, 12VDC, Code D
Direct Current Supply Voltage, 24VDC, Code E
Direct Current Supply Voltage, 24VDC, Code F
Direct Current Supply Voltage, 24VDC, Code G
Direct Current Supply Voltage, 24VDC, Code H
4.3.1.1 Overvoltage, Hot, 12VDC
4.3.1.2 Overvoltage, Room Temperature, 12VDC
4.3.2.2 Overvoltage, Hot, 24VDC
4.4 Superimposed Alternating Current, 12VDC, Severity 1
Superimposed Alternating Current, 12VDC, Severity 2
Superimposed Alternating Current, 12VDC, Severity 4
Superimposed Alternating Current, 24VDC, Severity 1
Superimposed Alternating Current, 24VDC, Severity 2
Superimposed Alternating Current, 24VDC, Severity 3
4.5 Slow Decrease and Increase of Supply Voltage, 12VDC, Code A
Slow Decrease and Increase of Supply Voltage, 12VDC, Code B
Slow Decrease and Increase of Supply Voltage, 12VDC, Code C
Slow Decrease and Increase of Supply Voltage, 12VDC, Code D
Slow Decrease and Increase of Supply Voltage, 24VDC, Code E
Slow Decrease and Increase of Supply Voltage, 24VDC, Code F
Slow Decrease and Increase of Supply Voltage, 24VDC, Code G
Slow Decrease and Increase of Supply Voltage, 24VDC, Code H
4.6.1 Momentary Drop in Supply Voltage, 12VDC, Code A
Momentary Drop in Supply Voltage, 12VDC, Code B
Momentary Drop in Supply Voltage, 12VDC, Code C
Momentary Drop in Supply Voltage, 12VDC, Code D
Momentary Drop in Supply Voltage, 24VDC, Code E
Momentary Drop in Supply Voltage, 24VDC, Code F
Momentary Drop in Supply Voltage, 24VDC, Code G
Momentary Drop in Supply Voltage, 24VDC, Code H
4.6.3 Starting Profile, 12VDC, Level I
Starting Profile, 12VDC, Level II
Starting Profile, 12VDC, Level III
Starting Profile, 12VDC, Level IV
Starting Profile, 24VDC, Level I
Starting Profile, 24VDC, Level II
Starting Profile, 24VDC, Level III
4.6.4.2.2 Load Dump Test A (without suppression) 12V
  Load Dump Test A (without suppression) 24V
4.6.4.2.3 Load Dump Test B (with suppression) 12V
  Load Dump Test B (with suppression) 24V
4.7.2.2 Reversed Voltage, 12VDC, Case 1
4.7.2.3 Reversed Voltage, 12VDC, Case 2
Reversed Voltage, 24VDC, Case 2
4.8.2 Ground Reference and Supply Offset, 12VDC
Ground Reference and Supply Offset, 24VDC
4.9.1 Open Circuit Test, 12VDC
Open Circuit Test, 24VDC
4.10 Short Circuit Protection, 12VDC
Short Circuit Protection, 24VDC
4.11 Withstand Voltage, 12VDC
Withstand Voltage, 24VDC
A.3.1 Load Dump Pulse Verification 12V 2ohm Load
Load Dump Pulse Verification 12V No Load
Load Dump Pulse Verification 24V 2ohm Load
Load Dump Pulse Verification 24V No Load