HDC101 |
Load Measurements - 270 V DC |
HDC102 - A |
Nominal (270 V DC) |
HDC102 - B |
NLSS (250 V DC) |
HDC102 - C |
NHSS (280 V DC) |
HDC103 |
Template |
HDC105 |
(270 VDC) - Repetitive Transient |
AA (280 VDC) - Overvoltage Transient (330 VDC) |
BB (280 VDC) - Overvoltage Transient (330 VDC) |
CC (280 VDC) - Overvoltage Transient (305 VDC) |
DD (280 VDC) - Overvoltage Transient (305 VDC) |
EE (280 VDC) - Overvoltage Transient x3 (330 VDC) |
FF (250 VDC) - Overvoltage Transient (330 VDC) |
GG (250 VDC) - Overvoltage Transient (330 VDC) |
HH (250 VDC) - Overvoltage Transient (305 VDC) |
II (250 VDC) - vervoltage Transient (305 VDC) |
JJ (250 VDC) - Overvoltage Transient x3 (330 VDC) |
KK (280 VDC) - Undervoltage Transient (200 VDC) |
LL (280 VDC) - Undervoltage Transient (200 VDC) |
MM (280 VDC) - Undervoltage Transient x3 (200 VDC) |
NN (250 VDC) - Undervoltage Transient (200 VDC) |
OO (250 VDC) - Undervoltage Transient (200 VDC) |
PP (250 VDC) - Undervoltage Transient x3 (200 VDC) |
QQ (280 VDC) - Combined Transient (200-330 VDC) |
RR (250 VDC) - Combined Transient (200-330 VDC) |
HDC201 |
A (270V) - Transfer Interrupt - Nominal Voltage (50 ms) |
B (250V) - Transfer Interrupt - NLSS Voltage (50 ms) |
C (280V) - Transfer Interrupt - NHSS Voltage (50 ms) |
D (270V) - Transfer Interrupt - Nominal Voltage (30 ms) |
E (250V) - Transfer Interrupt - NLSS Voltage (30 ms) |
F (280V) - Transfer Interrupt - NHSS Voltage (30 ms) |
G (270V) - Transfer Interrupt - Nominal Voltage (10 ms) |
H (250V) - Transfer Interrupt - NLSS Voltage (10 ms) |
I (280V) - Transfer Interrupt - NHSS Voltage (10 ms) |
J (270V) - Transfer Interrupt x3 - Nominal Voltage |
K (270V) - Transfer Interrupt - Overvoltage (330 VDC) |
L (270V) - Transfer Interrupt - Undervoltage (200 VDC) |
HDC301 |
A (270 V DC) - Undervoltage Transients (240 V DC) |
B (270 V DC) - Overvoltage Transients (290 V DC) |
HDC302 |
AA (280 V DC) - Overvoltage Transients (350 V DC) |
BB (280 V DC) - Overvoltage Transients (350 V DC) |
CC (280 V DC) - Overvoltage Transients x3 (350 V DC) |
DD (250 V DC) - Overvoltage Transients (350 V DC) |
EE (250 V DC) - Overvoltage Transients (350 V DC) |
FF (250 V DC) - Overvoltage Transients x3 (350 V DC) |
GG (280 V DC) - Undervoltage Transients (180 V DC) |
HH (280 V DC) - Undervoltage Transients (180 V DC) |
II (280 V DC) - Undervoltage Transients x3 (180 V DC) |
JJ (250 V DC) - Undervoltage Transients (180 V DC) |
KK (250 V DC) - Undervoltage Transients (180 V DC) |
LL (250 V DC) - Undervoltage Transients x3 (180 V DC) |
MM (280 V DC) - Combined Transients (180-350 V DC) |
HDC401 |
A (270 V DC) - Steady State Limits for Voltage (250 V DC) |
A (704B,C,D) (270 V DC) - Steady State Limits for Voltage (240 V DC) |
B (270 V DC) - Steady State Limits for Voltage (280 V DC) |
B (704B,C,D) (270 V DC) - Steady State Limits for Voltage (290 V DC) |
HDC501 |
A (704B,C) (270 V DC) - Starting Voltage Transients (155 V DC) |
AA (270 V DC) - Starting Voltage Transients (115 V DC) |
HDC601 |
A (270 V DC) - Power Failures (100 ms) |
B (270 V DC) - Power Failures (500 ms) |
C (270 V DC) - Power Failures (3000 ms) |
D (270 V DC) - Power Failures (7000 ms) |
HDC602 |
Correct Phase Connection (270 V DC) |
|
Phase Reversal (270 V DC) |
LDC101 |
Load Measurements - 28 V DC |
LDC102 |
A - Nominal (28 V DC) |
B - NLSS (22 V DC) |
C - NLSS (29 V DC) |
LDC103 |
Template |
LDC105 |
(28.5 VDC) - Repetitive Transient |
AA (29 VDC) - Overvoltage Transient (50 VDC) |
BB (29 VDC) - Overvoltage Transient (50 VDC) |
CC (29 VDC) - Overvoltage Transient (40 VDC) |
DD (29 VDC) - Overvoltage Transient (40 VDC) |
EE (29 VDC) - Overvoltage Transient x 3 (50 VDC) |
FF (22 VDC) - Overvoltage Transient (50 VDC) |
GG (22 VDC) - Overvoltage Transient (50 VDC) |
HH (22 VDC) - Overvoltage Transient (40 VDC) |
II (22 VDC) - Overvoltage Transient (40 VDC) |
JJ (22 VDC) - Overvoltage Transient x 3 (50 VDC) |
KK (29 VDC) - Undervoltage Transient (18 VDC) |
LL (29 VDC) - Undervoltage Transient (18 VDC) |
MM (29 VDC) - Undervoltage Transient x3 (18 VDC) |
NN (22 VDC) - Undervoltage Transient (18 VDC) |
OO (22 VDC) - Undervoltage Transient (18 VDC) |
PP (22 VDC) - Undervoltage Transient x3 (18 VDC) |
QQ (29 VDC) - Combined Transient (18-50 VDC) |
RR (22 VDC) - Combined Transient (18-50 VDC) |
LDC201 |
A (28V) - Transfer Interrupt - Nominal Voltage (50 ms) |
B (22V) - Transfer Interrupt - NLSS Voltage (50 ms) |
C (29V) - Transfer Interrupt - NHSS Voltage (50 ms) |
D (28V) - Transfer Interrupt - Nominal Voltage (30 ms) |
E (22V) - Transfer Interrupt - NLSS Voltage (30 ms) |
F (29V) - Transfer Interrupt - NHSS Voltage (30 ms) |
G (28V) - Transfer Interrupt - Nominal Voltage (10 ms) |
H (22V) - Transfer Interrupt - NLSS Voltage (10 ms) |
I (29V) - Transfer Interrupt - NHSS Voltage (10 ms) |
J (28V) - Transfer Interrupt x3 - Nominal Voltage |
K (28V) - Transfer Interrupt - Overvoltage (50 VDC) |
L (28V) - Transfer Interrupt - Undervoltage (18 VDC) |
LDC301 |
A (28 V DC) - Undervoltage Transients (20 V DC) |
B (28 V DC) - Overvoltage Transients (31,5 V DC) |
LDC302 |
AAA (29 V DC) - Overvoltage Transients (50 V DC) |
BBB (29 V DC) - Overvoltage Transients (50 V DC) |
CCC (29 V DC) - Overvoltage Transients x3 (50 V DC) |
DDD (22 V DC) - Overvoltage Transients (50 V DC) |
EEE (22 V DC) - Overvoltage Transients (50 V DC) |
FFF (22 V DC) - Overvoltage Transients x3 (50 V DC) |
GGG (29 V DC) - Undervoltage Transients (7 V DC) |
HHH (29 V DC) - Undervoltage Transients (7 V DC) |
III (29 V DC) - Undervoltage Transients x3 (7 V DC) |
JJJ (22 V DC) - Undervoltage Transients (7 V DC) |
KKK (22 V DC) - Undervoltage Transients (7 V DC) |
LLL (22 V DC) - Undervoltage Transients x3 (7 V DC) |
MMM (29 V DC) - Combined Transients (7-50 V DC) |
NNN (22 V DC) - Combined Transients (7-50 V DC) |
Template for A-V (704A) and AA-NN (704B-704D) |
LDC401 |
A (28 V DC) - Steady State Limits for Voltage (18 V DC) |
A (704A,C,D) (28 V DC) - Steady State Limits for Voltage (16 V DC) |
A (704B) (28 V DC) - Steady State Limits for Voltage (18 V DC) |
B (28 V DC) - Steady State Limits for Voltage (29 V DC) |
B (704B) (28 V DC) - Steady State Limits for Voltage (29 V DC) |
B (704C) (28 V DC) - Steady State Limits for Voltage (30 V DC) |
B (704D) (28 V DC) - Steady State Limits for Voltage (29 V DC) |
LDC501 |
A (704A,B,C) (28,5 V DC) - Starting Voltage Transients (16 V DC) |
AA (29 V DC) - Starting Voltage Transients (12 V DC) |
LDC601 |
A (28 V DC)- Power Failures (100 ms) |
B (28 V DC)- Power Failures (500 ms) |
C (28 V DC)- Power Failures (3000 ms) |
D (28 V DC)- Power Failures (7000 ms) |
LDC602 |
Correct Phase Connection (28 V DC) |
|
Phase Reversal (28 V DC) |
SAC101 |
Load Measurements - 115 V, 400Hz |
SAC102 |
A - Nominal Voltage, Nominal Frequency |
B - Nominal Voltage, NLSS Frequency |
C - Nominal Voltage, NHSS Frequency |
D - NLSS Voltage, Nominal Frequency |
E - NLSS Voltage, NLSS Frequency |
F - NLSS Voltage, NHSS Frequency |
G - NHSS Voltage, Nominal Frequency |
H - NHSS Voltage, NLSS Frequency |
I - NHSS Voltage, NHSS Frequency |
SAC105 |
A - 1Hz per second |
B - 5Hz per second |
C - 10Hz per second |
D - 25Hz per second |
E - 100Hz per second |
SAC106 (Ripple) |
A - 316 mVrms with 50 Hz Voltage Distortion |
B - 316 mVrms with 100 Hz Voltage Distortion |
C - 1580 mVrms with 500 Hz Voltage Distortion |
D - 3160 mVrms with 1 kHz Voltage Distortion |
E - 3160 mVrms with 2 kHz Voltage Distortion |
F - 3160 mVrms with 3 kHz Voltage Distortion |
G - 1900 mVrms with 5 kHz Voltage Distortion |
H - 950 mVrms with 10 kHz Voltage Distortion |
SAC108 |
A - 115 Vrms with +100 mV DC offset |
|
B - 115 Vrms with -100 mV DC offset |
SAC109 |
(MIL-STD-704A version) Test Conditions A-O Template |
|
AA - Overvoltage Transients (140 Vrms) |
|
A-O Template (for MIL-STD-704A version) |
|
BB - Overvoltage Transients (140 Vrms) |
|
CC - Overvoltage Transients (160 Vrms) |
|
DD - Overvoltage Transients (160 Vrms) |
|
EE - Overvoltage Transients (180 Vrms) |
|
FF - Overvoltage Transients (180 Vrms) |
|
GG - Overvoltage Transients x3 (180 Vrms) |
|
HH - Undervoltage Transients (90 Vrms) |
|
II - Undervoltage Transients (90 Vrms) |
|
JJ - Undervoltage Transients (80 Vrms) |
|
KK - Undervoltage Transients (80 Vrms) |
|
LL - Undervoltage Transients x3 (80 Vrms) |
|
MM - Combined Transients (80-180 Vrms) |
|
Repetitive Normal Voltage Transients |
SAC110 |
(MIL-STD-704A version) Test Conditions A-I Template |
|
AA - Overfrequency Transients (410 Hz) |
|
BB - Overfrequency Transients (420 Hz) |
|
CC - Overfrequency Transients (425 Hz) |
|
DD - Overfrequency Transients (425-410 Hz) |
|
EE - Underfrequency Transients (390 Hz) |
|
FF - Underfrequency Transients (380 Hz) |
|
GG - Underfrequency Transients (375 Hz) |
|
HH - Underfrequency Transients (375-390 Hz) |
|
II - Combined Frequency Transients (375-425 Hz) |
SAC201 |
A - Transfer Interrupt - Nominal Voltage (50 ms) |
|
B - Transfer Interrupt - NLSS Voltage (50 ms) |
|
C - Transfer Interrupt - NHSS Voltage (50 ms) |
|
D - Transfer Interrupt - Nominal Voltage (30 ms) |
|
E - Transfer Interrupt - NLSS Voltage (30 ms) |
|
F - Transfer Interrupt - NHSS Voltage (30 ms) |
|
G - Transfer Interrupt - Nominal Voltage (10 ms) |
|
H - Transfer Interrupt - NLSS Voltage (10 ms) |
|
I - Transfer Interrupt - NHSS Voltage (10 ms) |
|
J - Transfer Interrupt x3 - Nominal Voltage (50 ms) |
|
K - Transfer Interrupt - Nominal Voltage + Overvoltage |
|
L - Transfer Interrupt - Nominal Voltage + Undervoltage |
SAC301 |
A - Abnormal Steady State Limits (115 Vrms, 380 Hz) |
|
B - Abnormal Steady State Limits (115 Vrms, 420 Hz) |
|
C - Abnormal Steady State Limits (100 Vrms, 400 Hz) |
|
D - Abnormal Steady State Limits (100 Vrms, 380 Hz) |
|
E - Abnormal Steady State Limits (100 Vrms, 420 Hz) |
|
F - Abnormal Steady State Limits (125 Vrms, 400 Hz) |
|
G - Abnormal Steady State Limits (125 Vrms, 380 Hz) |
|
H - Abnormal Steady State Limits (125 Vrms, 420 Hz) |
SAC302 |
A (704A only) - Overvoltage Transients (140 Vrms) |
|
AA - Overvoltage Transients (140 Vrms) |
|
B (704A only) - Overvoltage Transients (140 Vrms) |
|
BB - Overvoltage Transients (140 Vrms) |
|
C (704A only) - Overvoltage Transients (160 Vrms) |
|
CC - Overvoltage Transients (160 Vrms) |
|
D (704A only) - Overvoltage Transients (160 Vrms) |
|
DD - Overvoltage Transients (160 Vrms) |
|
E (704A only) - Overvoltage Transients (180 Vrms) |
|
EE - Overvoltage Transients (180 Vrms) |
|
F (704A only) - Overvoltage Transients (180 Vrms) |
|
FF - Overvoltage Transients (180 Vrms) |
|
G (704A only) - Overvoltage Transients x3 (180 Vrms) |
|
GG - Overvoltage Transients x3 (180 Vrms) |
|
H (704A only) - Undervoltage Transients (85 Vrms) |
|
HH - Undervoltage Transients (85 Vrms) |
|
I (704A only) - Undervoltage Transients (85 Vrms) |
|
II - Undervoltage Transients (85 Vrms) |
|
J (704A only) - Undervoltage Transients (75 Vrms) |
|
JJ - Undervoltage Transients (66 Vrms) |
|
K (704A only) - Undervoltage Transients (75 Vrms) |
|
KK - Undervoltage Transients (65 Vrms) |
|
L (704A only) - Undervoltage Transients (45 Vrms) |
|
LL - Undervoltage Transients (45 Vrms) |
|
M (704A only) - Undervoltage Transients (45 Vrms) |
|
MM - Undervoltage Transients (45 Vrms) |
|
N (704A only) - Undervoltage Transients x3 (45 Vrms) |
|
NN - Undervoltage Transients x3 (45 Vrms) |
|
O (704A only) - Combined Transients (45-180 Vrms) |
|
OO - Combined Transients (180 Vrms) |
SAC303 |
A (704A) - Overfrequency Transients (480 Hz) |
|
AA - Overfrequency Transients (480 Hz) |
|
B (704A) - Overfrequency Transients (480 Hz) |
|
BB - Overfrequency Transients (480 Hz) |
|
C (704A) - Underfrequency Transients (320 Hz) |
|
CC - Underfrequency Transients (320 Hz) |
|
D (704A) - Underfrequency Transients (320 Hz) |
|
DD - Underfrequency Transients (320 Hz) |
|
E (704A) - Combined Transients (320-480 Hz) |
|
EE - Combined Transients (320-480 Hz) |
SAC401 |
A - Emergency Steady State Limits - 115 V, 393 Hz |
|
A (704A-D) - Emergency Steady State Limits - 115 V, 360 Hz |
|
B - Emergency Steady State Limits - 115 V, 407 Hz |
|
B (704A-D) - Emergency Steady State Limits - 115 V, 440 Hz |
|
C - Emergency Steady State Limits - 104 V, 400 Hz |
|
C (704A,C,D) - Emergency Steady State Limits - 104 V, 400 Hz |
|
C (704B) - Emergency Steady State Limits - 102 V, 400 Hz |
|
D - Emergency Steady State Limits - 104 V, 393 Hz |
|
D (704A,C,D) - Emergency Steady State Limits - 104 V, 360 Hz |
|
D (704B) - Emergency Steady State Limits - 102 V, 360 Hz |
|
E - Emergency Steady State Limits - 104 V, 407 Hz |
|
E (704A,C,D) - Emergency Steady State Limits - 104 V, 440 Hz |
|
E (704B) - Emergency Steady State Limits - 102 V, 440 Hz |
|
F - Emergency Steady State Limits - 118 V, 400 Hz |
|
F (704A,C,D) - Emergency Steady State Limits - 122 V, 400 Hz |
|
F (704B) - Emergency Steady State Limits - 124 V, 400 Hz |
|
G - Emergency Steady State Limits - 118 V, 393 Hz |
|
G (704A,C,D) - Emergency Steady State Limits - 122 V, 360 Hz |
|
G (704B) - Emergency Steady State Limits - 124 V, 360 Hz |
|
H - Emergency Steady State Limits - 118 V, 407 Hz |
|
H (704A,C,D) - Emergency Steady State Limits - 122 V, 440 Hz |
|
H (704B) - Emergency Steady State Limits - 124 V, 440 Hz |
SAC601 |
A - Power Failures (100 ms) |
|
B - Power Failures (500 ms) |
|
C - Power Failures (3000 ms) |
|
D - Power Failures (7000 ms) |
SAC603 |
Correct Phase Connection |
|
Phase Reversal |
SVF101 |
Load Measurements - 115 V, 360Hz |
|
Load Measurements - 115 V, 400Hz |
|
Load Measurements - 115 V, 600Hz |
|
Load Measurements - 115 V, 800Hz |
SVF102 |
Template |
SVF105 |
A (362 Hz) - 1Hz per second |
|
A (400 Hz) - 1Hz per second |
|
A (600 Hz) - 1Hz per second |
|
A (798 Hz) - 1Hz per second |
|
B (362 Hz) - 5Hz per second |
|
B (400 Hz) - 5Hz per second |
|
B (600 Hz) - 5Hz per second |
|
B (798 Hz) - 5Hz per second |
|
C (362 Hz) - 10Hz per second |
|
C (400 Hz) - 10Hz per second |
|
C (600 Hz) - 10Hz per second |
|
C (798 Hz) - 10Hz per second |
|
D (362 Hz) - 25Hz per second |
|
D (400 Hz) - 25Hz per second |
|
D (600 Hz) - 25Hz per second |
|
D (798 Hz) - 25Hz per second |
|
E (362 Hz) - 100Hz per second |
|
E (400 Hz) - 100Hz per second |
|
E (600 Hz) - 100Hz per second |
|
E (798 Hz) - 100Hz per second |
SVF106 (Ripple) |
A - 316 mVrms with 50 Hz Voltage Distortion |
|
B - 316 mVrms with 100 Hz Voltage Distortion |
|
C - 1580 mVrms with 500 Hz Voltage Distortion |
|
D - 3160 mVrms with 1 kHz Voltage Distortion |
|
E - 3160 mVrms with 2 kHz Voltage Distortion |
|
F - 3160 mVrms with 3 kHz Voltage Distortion |
|
G - 1900 mVrms with 5 kHz Voltage Distortion |
|
H - 950 mVrms with 10 kHz Voltage Distortion |
SVF108 |
A (360 Hz) - 115 Vrms with +100 mV DC offset |
|
A (400 Hz) - 115 Vrms with +100 mV DC offset |
|
A (600 Hz) - 115 Vrms with +100 mV DC offset |
|
A (800 Hz) - 115 Vrms with +100 mV DC offset |
|
B (360 Hz) - 115 Vrms with -100 mV DC offset |
|
B (400 Hz) - 115 Vrms with -100 mV DC offset |
|
B (600 Hz) - 115 Vrms with -100 mV DC offset |
|
B (800 Hz) - 115 Vrms with -100 mV DC offset |
SVF109 |
A (360 Hz) - Overvoltage Transients (140 Vrms) |
|
A (400 Hz) - Overvoltage Transients (140 Vrms) |
|
A (600 Hz) - Overvoltage Transients (140 Vrms) |
|
A (800 Hz) - Overvoltage Transients (140 Vrms) |
|
B (360 Hz) - Overvoltage Transients (140 Vrms) |
|
B (400 Hz) - Overvoltage Transients (140 Vrms) |
|
B (600 Hz) - Overvoltage Transients (140 Vrms) |
|
B (800 Hz) - Overvoltage Transients (140 Vrms) |
|
C (360 Hz) - Overvoltage Transients (160 Vrms) |
|
C (400 Hz) - Overvoltage Transients (160 Vrms) |
|
C (600 Hz) - Overvoltage Transients (160 Vrms) |
|
C (800 Hz) - Overvoltage Transients (160 Vrms) |
|
D (360 Hz) - Overvoltage Transients (160 Vrms) |
|
D (400 Hz) - Overvoltage Transients (160 Vrms) |
|
D (600 Hz) - Overvoltage Transients (160 Vrms) |
|
D (800 Hz) - Overvoltage Transients (160 Vrms) |
|
E (360 Hz) - Overvoltage Transients (180 Vrms) |
|
E (400 Hz) - Overvoltage Transients (180 Vrms) |
|
E (600 Hz) - Overvoltage Transients (180 Vrms) |
|
E (800 Hz) - Overvoltage Transients (180 Vrms) |
|
F (360 Hz) - Overvoltage Transients (180 Vrms) |
|
F (400 Hz) - Overvoltage Transients (180 Vrms) |
|
F (600 Hz) - Overvoltage Transients (180 Vrms) |
|
F (800 Hz) - Overvoltage Transients (180 Vrms) |
|
G (360 Hz) - Overvoltage Transients x3 (180 Vrms) |
|
G (400 Hz) - Overvoltage Transients x3 (180 Vrms) |
|
G (600 Hz) - Overvoltage Transients x3 (180 Vrms) |
|
G (800 Hz) - Overvoltage Transients x3 (180 Vrms) |
|
H (360 Hz) - Undervoltage Transients (90 Vrms) |
|
H (400 Hz) - Undervoltage Transients (90 Vrms) |
|
H (600 Hz) - Undervoltage Transients (90 Vrms) |
|
H (800 Hz) - Undervoltage Transients (90 Vrms) |
|
I (360 Hz) - Undervoltage Transients (90 Vrms) |
|
I (400 Hz) - Undervoltage Transients (90 Vrms) |
|
I (600 Hz) - Undervoltage Transients (90 Vrms) |
|
I (800 Hz) - Undervoltage Transients (90 Vrms) |
|
J (360 Hz) - Undervoltage Transients (80 Vrms) |
|
J (400 Hz) - Undervoltage Transients (80 Vrms) |
|
J (600 Hz) - Undervoltage Transients (80 Vrms) |
|
J (800 Hz) - Undervoltage Transients (80 Vrms) |
|
K (360 Hz) - Undervoltage Transients (80 Vrms) |
|
K (400 Hz) - Undervoltage Transients (80 Vrms) |
|
K (600 Hz) - Undervoltage Transients (80 Vrms) |
|
K (800 Hz) - Undervoltage Transients (80 Vrms) |
|
L (360 Hz) - Undervoltage Transients x3 (80 Vrms) |
|
L (400 Hz) - Undervoltage Transients x3 (80 Vrms) |
|
L (600 Hz) - Undervoltage Transients x3 (80 Vrms) |
|
L (800 Hz) - Undervoltage Transients x3 (80 Vrms) |
|
M (360 Hz) - Combined Transients (80-180 Vrms) |
|
M (400 Hz) - Combined Transients (80-180 Vrms) |
|
M (600 Hz) - Combined Transients (80-180 Vrms) |
|
M (800 Hz) - Combined Transients (80-180 Vrms) |
|
Repetitive Normal Voltage Transients (360 Hz) |
|
Repetitive Normal Voltage Transients (400 Hz) |
|
Repetitive Normal Voltage Transients (600 Hz) |
|
Repetitive Normal Voltage Transients (800 Hz) |
SVF110 |
A - Overfrequency Transients (360-800 Hz) |
|
B - Overfrequency Transients (360-800 Hz) |
|
C - Overfrequency Transients (360-600 Hz) |
|
D - Overfrequency Transients (360-600 Hz) |
|
E - Underfrequency Transients (800-360 Hz) |
|
F - Underfrequency Transients (800-360 Hz) |
|
G - Underfrequency Transients (800-600 Hz) |
|
H - Underfrequency Transients (800-600 Hz) |
|
I - Combined Frequency Transients (800-360 Hz) |
SVF201 |
A (360 Hz) - Transfer Interrupt - Nominal Voltage (50 ms) |
|
A (400 Hz) - Transfer Interrupt - Nominal Voltage (50 ms) |
|
A (600 Hz) - Transfer Interrupt - Nominal Voltage (50 ms) |
|
A (800 Hz) - Transfer Interrupt - Nominal Voltage (50 ms) |
|
B (360 Hz) - Transfer Interrupt - NLSS Voltage (50 ms) |
|
B (400 Hz) - Transfer Interrupt - NLSS Voltage (50 ms) |
|
B (600 Hz) - Transfer Interrupt - NLSS Voltage (50 ms) |
|
B (800 Hz) - Transfer Interrupt - NLSS Voltage (50 ms) |
|
C (360 Hz) - Transfer Interrupt - NHSS Voltage (50 ms) |
|
C (400 Hz) - Transfer Interrupt - NHSS Voltage (50 ms) |
|
C (600 Hz) - Transfer Interrupt - NHSS Voltage (50 ms) |
|
C (800 Hz) - Transfer Interrupt - NHSS Voltage (50 ms) |
|
D (360 Hz) - Transfer Interrupt - Nominal Voltage (30 ms) |
|
D (400 Hz) - Transfer Interrupt - Nominal Voltage (30 ms) |
|
D (600 Hz) - Transfer Interrupt - Nominal Voltage (30 ms) |
|
D (800 Hz) - Transfer Interrupt - Nominal Voltage (30 ms) |
|
E (360 Hz) - Transfer Interrupt - NLSS Voltage (30 ms) |
|
E (400 Hz) - Transfer Interrupt - NLSS Voltage (30 ms) |
|
E (600 Hz) - Transfer Interrupt - NLSS Voltage (30 ms) |
|
E (800 Hz) - Transfer Interrupt - NLSS Voltage (30 ms) |
|
F (360 Hz) - Transfer Interrupt - NHSS Voltage (30 ms) |
|
F (400 Hz) - Transfer Interrupt - NHSS Voltage (30 ms) |
|
F (600 Hz) - Transfer Interrupt - NHSS Voltage (30 ms) |
|
F (800 Hz) - Transfer Interrupt - NHSS Voltage (30 ms) |
|
G (360 Hz) - Transfer Interrupt - Nominal Voltage (10 ms) |
|
G (400 Hz) - Transfer Interrupt - Nominal Voltage (10 ms) |
|
G (600 Hz) - Transfer Interrupt - Nominal Voltage (10 ms) |
|
G (800 Hz) - Transfer Interrupt - Nominal Voltage (10 ms) |
|
H (360 Hz) - Transfer Interrupt - NLSS Voltage (10 ms) |
|
H (400 Hz) - Transfer Interrupt - NLSS Voltage (10 ms) |
|
H (600 Hz) - Transfer Interrupt - NLSS Voltage (10 ms) |
|
H (800 Hz) - Transfer Interrupt - NLSS Voltage (10 ms) |
|
I (360 Hz) - Transfer Interrupt - NHSS Voltage (10 ms) |
|
I (400 Hz) - Transfer Interrupt - NHSS Voltage (10 ms) |
|
I (600 Hz) - Transfer Interrupt - NHSS Voltage (10 ms) |
|
I (800 Hz) - Transfer Interrupt - NHSS Voltage (10 ms) |
|
J (360 Hz) - Transfer Interrupt x3 - Nominal Voltage |
|
J (400 Hz) - Transfer Interrupt x3 - Nominal Voltage |
|
J (600 Hz) - Transfer Interrupt x3 - Nominal Voltage |
|
J (800 Hz) - Transfer Interrupt x3 - Nominal Voltage |
|
K (360 Hz) - Transfer Interrupt - Overvoltage |
|
K (400 Hz) - Transfer Interrupt - Overvoltage |
|
K (600 Hz) - Transfer Interrupt - Overvoltage |
|
K (800 Hz) - Transfer Interrupt - Overvoltage |
|
L (360 Hz) - Transfer Interrupt - Undervoltage |
|
L (400 Hz) - Transfer Interrupt - Undervoltage |
|
L (600 Hz) - Transfer Interrupt - Undervoltage |
|
L (800 Hz) - Transfer Interrupt - Undervoltage |
SVF301 |
A - Abnormal Steady State Limits (100 Vrms, 400 Hz) |
|
B - Abnormal Steady State Limits (100 Vrms, 360 Hz) |
|
C - Abnormal Steady State Limits (100 Vrms, 600 Hz) |
|
D - Abnormal Steady State Limits (100 Vrms, 800 Hz) |
|
E - Abnormal Steady State Limits (125 Vrms, 400 Hz) |
|
F - Abnormal Steady State Limits (125 Vrms, 360 Hz) |
|
G - Abnormal Steady State Limits (125 Vrms, 600 Hz) |
|
H - Abnormal Steady State Limits (125 Vrms, 800 Hz) |
SVF302 |
Abnormal Transients Template (360 Hz) |
|
Abnormal Transients Template (400 Hz) |
|
Abnormal Transients Template (600 Hz) |
|
Abnormal Transients Template (800 Hz) |
SVF303 |
A (360 Hz) - Overfrequency Transients (800 Hz) |
|
B (360 Hz) - Overfrequency Transients (800 Hz) |
|
C (360 Hz) - Overfrequency Transients (600 Hz) |
|
D (360 Hz) - Overfrequency Transients (600 Hz) |
|
E (800 Hz) - Underfrequency Transients (360 Hz) |
|
F (800 Hz) - Underfrequency Transients (360 Hz) |
|
G (800 Hz) - Underfrequency Transients (600 Hz) |
|
H (800 Hz) - Underfrequency Transients (600 Hz) |
|
I (600 Hz) - Combined Transients (360-800 Hz) |
SVF401 |
Template |
SVF601 |
A (360 Hz) - Power Failures (100 ms) |
|
A (400 Hz) - Power Failures (100 ms) |
|
A (600 Hz) - Power Failures (100 ms) |
|
A (800 Hz) - Power Failures (100 ms) |
|
B (360 Hz) - Power Failures (500 ms) |
|
B (400 Hz) - Power Failures (500 ms) |
|
B (600 Hz) - Power Failures (500 ms) |
|
B (800 Hz) - Power Failures (500 ms) |
|
C (360 Hz) - Power Failures (3000 ms) |
|
C (400 Hz) - Power Failures (3000 ms) |
|
C (600 Hz) - Power Failures (3000 ms) |
|
C (800 Hz) - Power Failures (3000 ms) |
|
D (360 Hz) - Power Failures (7000 ms) |
|
D (400 Hz) - Power Failures (7000 ms) |
|
D (600 Hz) - Power Failures (7000 ms) |
|
D (800 Hz) - Power Failures (7000 ms) |
SVF603 |
Correct Phase Configuration (800 Hz) |
|
Phase Reversal (360 Hz) |
|
Phase Reversal (400 Hz) |
|
Phase Reversal (600 Hz) |
SXF101 |
Load Measurements - 115 V, 60Hz |
SXF102 |
A - 115 V, 60Hz |
|
B - 115 V, 59.5Hz |
|
C - 115 V, 60.5Hz |
|
D - 105 V, 60Hz |
|
E - 105 V, 59.5Hz |
|
F - 105 V, 60.5Hz |
|
G - 125 V, 60Hz |
|
H - 125 V, 59.5Hz |
|
I - 125 V, 60.5Hz |
SXF105 |
A (60 Hz) - 0.1Hz per second |
|
B (60 Hz) - 0.5Hz per second |
|
C (60 Hz) - 4Hz per second |
|
D (60 Hz) - 25Hz per second |
|
E (60 Hz) - 15Hz per second |
SXF106 (Ripple) |
A (60 Hz) - 1000 mVrms with 50 Hz Voltage Distortion |
|
B (60 Hz) - 3162 mVrms with 150 Hz Voltage Distortion |
|
C (60 Hz) - 3162 mVrms with 450 Hz Voltage Distortion |
|
D (60 Hz) - 1333 mVrms with 1 kHz Voltage Distortion |
|
E (60 Hz) - 473 mVrms with 3 kHz Voltage Distortion |
|
F (60 Hz) - 282 mVrms with 5 kHz Voltage Distortion |
|
G (60 Hz) - 150 mVrms with 10 kHz Voltage Distortion |
SXF108 |
A (60 Hz) - 115 Vrms with +100 mV DC offset |
|
B (60 Hz) - 115 Vrms with -100 mV DC offset |
SXF109 |
A (60 Hz) - Overvoltage Transients (152 Vrms) |
|
B (60 Hz) - Overvoltage Transients (130 Vrms) |
|
C (60 Hz) - Overvoltage Transients (130 Vrms) |
|
D (60 Hz) - Overvoltage Transients x3 (130 Vrms) |
|
E (60 Hz) - Undervoltage Transients (70 Vrms) |
|
F (60 Hz) - Undervoltage Transients (70 Vrms) |
|
G (60 Hz) - Undervoltage Transients (70 Vrms) |
|
H (60 Hz) - Undervoltage Transients x3 (70 Vrms) |
|
I (60 Hz) - Combined Transients (70-130 Vrms) |
|
Repetitive Normal Voltage Transients (100-128 Vrms) |
SXF110 |
A - Overfrequency Transients (61 Hz) |
|
B - Overfrequency Transients (61 Hz) |
|
C - Underfrequency Transients (59 Hz) |
|
D - Underfrequency Transients (59 Hz) |
|
E - Combined Frequency Transients (59-61 Hz) |
SXF201 |
A (60 Hz) - Transfer Interrupt - Nominal Voltage (50 ms) |
|
B (60 Hz) - Transfer Interrupt - NLSS Voltage (50 ms) |
|
C (60 Hz) - Transfer Interrupt - NHSS Voltage (50 ms) |
|
D (60 Hz) - Transfer Interrupt - Nominal Voltage (30 ms) |
|
E (60 Hz) - Transfer Interrupt - NLSS Voltage (30 ms) |
|
F (60 Hz) - Transfer Interrupt - NHSS Voltage (30 ms) |
|
G (60 Hz) - Transfer Interrupt - Nominal Voltage (10 ms) |
|
H (60 Hz) - Transfer Interrupt - NLSS Voltage (10 ms) |
|
I (60 Hz) - Transfer Interrupt - NHSS Voltage (10 ms) |
|
J (60 Hz) - Transfer Interrupt x3 - Nominal Voltage |
|
K (60 Hz) - Transfer Interrupt - Overvoltage |
|
L (60 Hz) - Transfer Interrupt - Undervoltage |
SXF301 |
A - Abnormal Steady State Limits (115 Vrms, 59,5 Hz) |
|
B - Abnormal Steady State Limits (115 Vrms, 60,5 Hz) |
|
C - Abnormal Steady State Limits (100 Vrms, 60 Hz) |
|
D - Abnormal Steady State Limits (100 Vrms, 59,5 Hz) |
|
E - Abnormal Steady State Limits (100 Vrms, 60,5 Hz) |
|
F - Abnormal Steady State Limits (128 Vrms, 60 Hz) |
|
G - Abnormal Steady State Limits (128 Vrms, 59,5 Hz) |
|
H - Abnormal Steady State Limits (128 Vrms, 60,5 Hz) |
SXF302 |
A (60 Hz) - Overvoltage Transients (180 Vrms) |
|
B (60 Hz) - Overvoltage Transients (180 Vrms) |
|
C (60 Hz) - Overvoltage Transients (160 Vrms) |
|
D (60 Hz) - Overvoltage Transients (160 Vrms) |
|
E (60 Hz) - Overvoltage Transients x3 (180 Vrms) |
|
F (60 Hz) - Undervoltage Transients (50 Vrms) |
|
G (60 Hz) - Undervoltage Transients (50 Vrms) |
|
H (60 Hz) - Undervoltage Transients (70 Vrms) |
|
I (60 Hz) - Undervoltage Transients (70 Vrms) |
|
J (60 Hz) - Undervoltage Transients x3 (50 Vrms) |
|
K (60 Hz) - Combined Transients (50-180 Vrms) |
SXF303 |
A (60 Hz) - Overfrequency Transients (61 Hz) |
|
B (60 Hz) - Overfrequency Transients (61 Hz) |
|
C (60 Hz) - Underfrequency Transients (50 Hz) |
|
D (60 Hz) - Underfrequency Transients (50 Hz) |
|
E (60 Hz) - Combined Frequency Transients (50-61 Hz) |
SXF401 |
A - 115 V, 60HzA - 115 V, 60Hz |
|
B - 115 V, 59.5Hz |
|
C - 115 V, 60.5Hz |
|
D - 105 V, 60Hz |
|
E - 105 V, 59.5Hz |
|
F - 105 V, 60.5Hz |
|
G - 125 V, 60Hz |
|
H - 125 V, 59.5Hz |
|
I - 125 V, 60.5Hz |
SXF601 |
A (60 Hz) - Power Failures (100 ms) |
|
B (60 Hz) - Power Failures (500 ms) |
|
C (60 Hz) - Power Failures (2000 ms) |
SXF603 |
Correct Phase Connection (60 Hz) |
|
Phase Reversal (60 Hz) |