8.2.1 - Jump Start (July 2010) |
8.2.2 - Reverse Polarity (July 2010) |
8.2.3 - Overvoltage (with overvoltage protection) (July 2010) |
8.2.3 - Overvoltage (without overvoltage protection) (July 2010) |
8.2.4 - State Change Waveform Characterization (July 2010) |
9.2.1 - Parasitic Current (July 2010) |
9.2.2 - Power Supply Interruptions, 12V, Code A (July 2010) |
9.2.2 - Power Supply Interruptions, 12V, Code B (July 2010) |
9.2.2 - Power Supply Interruptions, 12V, Code C & D (July 2010) |
9.2.2 - Power Supply Interruptions, 12V, Code E (July 2010) |
9.2.2 - Power Supply Interruptions, 12V, Code F (July 2010) |
9.2.3 - Battery Voltage Dropout, 12VDC, Code A (July 2010) |
9.2.3 - Battery Voltage Dropout, 12VDC, Code B (July 2010) |
9.2.3 - Battery Voltage Dropout, 12VDC, Code C & D (July 2010) |
9.2.3 - Battery Voltage Dropout, 12VDC, Code E (July 2010) |
9.2.3 - Battery Voltage Dropout, 12VDC, Code F (July 2010) |
9.2.4 - Sinusoidal Superimposed Voltage, 12VDC (July 2010) |
9.2.5 - Pulse Superimposed Voltage, 12VDC, U(p) only (July 2010) |
9.2.7 - Continuous Short Circuit to Battery and to Ground, 12VDC, Code A (July 2010) |
9.2.7 - Continuous Short Circuit to Battery and to Ground, 12VDC, Code B (July 2010) |
9.2.7 - Continuous Short Circuit to Battery and to Ground, 12VDC, Code C (July 2010) |
9.2.7 - Continuous Short Circuit to Battery and to Ground, 12VDC, Code D (July 2010) |
9.2.7 - Continuous Short Circuit to Battery and to Ground, 12VDC, Code E (July 2010) |
9.2.7 - Continuous Short Circuit to Battery and to Ground, 12VDC, Code F (July 2010) |
9.2.8 - Ground Interconnect Short to Battery, 12VDC, Code A, B, C, E, F (July 2010) |
9.2.8 - Ground Interconnect Short to Battery, 12VDC, Code D (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity I, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity I, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity II, Ua = 2.5V, Durabil, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity II, Ua = 2.5V, Function, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity II, Ua = 3V, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity II, Ua = 3V, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity III, Ua = 2.5V, Durabil, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity III, Ua = 2.5V, Function, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity III, Ua = 3V, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity III, Ua = 3V, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity III, Ua = 4V, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity III, Ua = 4V, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 2.5V, Durabil, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 2.5V, Function, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 3V, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 3V, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 4V, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 4V, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 5V, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, GMW3097 pulse 4, severity IV, Ua = 5V, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 1, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 1, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 2, Durbility, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 2, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 3, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 3, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 4, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 4, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 5, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 5, Functional, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 6, Durability, 12VDC (July 2010) |
9.2.17 - Crank Pulse Capability and Durability, Waveform 6, Functional, 12VDC (July 2010) |
9.3.1 - Vibration with Thermal Cycling, 12VDC (July 2010) |
9.3.2 - Post Thermal Fatigue Vibration, 12VDC (July 2010) |
9.3.3 - Mechanical Shock - Pothole, 12VDC (July 2010) |
9.3.5 - Mechanical Shock - Closure Slam, 12VDC (July 2010) |
9.3.9 - Connector Installation Abuse - Side Force, 12VDC (July 2010) |
9.3.10 - Connector Installation Abuse - Foot Load, 12VDC (July 2010) |
9.4.1 - High Temperature Degradation, 12VDC (July 2010) |
9.4.3 - Power Temperature Cycle, 12VDC (July 2010) |
9.4.5 - Humid Heat Cyclic, 12VDC (July 2010) |
9.4.6 - Humid Heat Constant, 12VDC (July 2010) |
9.4.8 - Salt Spray, IP Water Code 3 or 6K, 12VDC (July 2010) |
9.4.8 - Salt Spray, IP Water Code 6K or 8 or 9K non-int comp with direct exp to salt |
9.4.8 - Salt Spray, IP Water Code 6K or 8 or 9K non-interior component with direct exposure to salt |
9.4.8 - Salt Spray, IP Water Code 6K or 8 or 9K, 12VDC (July 2010) |
9.5.3 - Seal, 12VDC (July 2010) |
9.5.4 - Water Freeze, 12VDC (July 2010) |
9.5.5 - Sugar Water Function Impairment, 12VDC (July 2010) |