8508

DC-50kHz Switch-Mode Amplifier

8508

8 kW (up to 100 kVA), up to 160A continuous, three-phase

Key Performance Capabilities:
  • Bandwidth: DC to 50 kHz
  • Voltage: 0 to 260 VRMS; 0 to 400 VDC
  • Slew rate: Up to 80 V/µs
  • Current: Up to 160 ARMS*
  • Distortion: <0.2%
  • Power: 8 kW*
  • Power levels up to 5X rated power when driving reactive loads
  • High power efficiency and density

*Models available with output power from 4 kW to 24 kW (capable of up to 100 kVA).

SKU: N/A Categories: ,
OVERVIEW

8508 amplifiers are 400Vp, low-noise, DC-to-50-kHz switch-mode amplifiers. They are fast enough for DC automotive dropout testing and capable of AC voltages required for ISO 61000 and Aviation testing. Plus, they have low enough noise and distortion specifications to be the reference power source in power quality measurements. The 8508 amplifier is capable of reproducing AC, DC and AC+DC waveforms into loads from a dead short to high impedance. It can be used to simulate a battery at 13.5 VDC or be an AC source with a L-N potential of up to 140 VAC. Rated current, for a given voltage, is available for all waveform types (AC, DC or AC+DC) at frequencies from DC to 50 kHz. Voltages from 0 to 260 VRMS are available with no changes in configuration.

The 8508 excels when it comes to driving reactive loads. As frequencies increase, the effective impedance of the load becomes a much larger part of the total load to be driven (especially with inductive loads like coils). However, when driving reactive loads, the 8508 is capable of receiving, reprocessing and returning to the load up to 5X its rated power. The result is a bench top system capable of 10 kVA+ output while drawing less than 8 kW of AC mains power.

Configurable:

A key to everyday product usability is quick and easy product (re)configuration. The 8500 Series provides all key configuration controls on the back panel of the unit. Configuration options available include:

  • GAIN: Fixed or variable gain (0 to 40)
  • CURRENT LIMIT: From 5% to rated limit (to protect fragile DUTs or where specified in the Standard)
  • DC CONTROL: DC enabled or DC blocked and DC Servo (for driving transformer-coupled loads or coils)
  • INPUT: Balanced and/or unbalanced
  • MODE: Voltage source or current source
  • OUTPUT IMPEDANCE: Variable from 0 to 1 ohm (Voltage mode)
  • SENSE: Correction to voltage drops to the load
OUTPUT CHART

Output

CONTINUOUS AC OUTPUT CURRENT CONTINUOUS DC OUTPUT CURRENT*
VOLTS
RMS
8504 8508 8512 8516 8520 8524 VOLTS
DC
8504 8508 8512 8516 8520 8524
60 60 120 180 240 300 360 13.5 80 160 240 320 400 480
120 32 64 96 128 160 192 24 80 160 240 320 400 480
230 10 20 30 40 50 60 48 75 150 225 300 375 425

Note: 8504 power ratings shown are for unit configured for 240VAC. At output voltages above 90VAC, units configured for 120VAC mains input may be breaker limited. Contact AE Techron for 120VAC performance ratings. Performance data is for a purely resistive load; performance will be improved into loads that are partially or completely reactive.

 
PERFORMANCE

SPECIFICATIONS

Performance Specifications

  • Operating Modes: AC, DC and AC + DC
  • Frequency, AC Mode Output (-3 dB): DC – 50 kHz
  • Max Voltage Ranges (no load):
    • AC: 0 – 260 VRMS
    • AC + DC: 0 – ±400 VP
  • Max Continuous Output Current: 160A RMS
  • Surge Rating: 2X power at up to 400Vp or 300A
  • Apparent Power Rating: Up to 5X continuous power rating at up to 400 Vp or 300A
  • Supply Voltage: Three-phase, 208V ±10%, 30A, 50/60 Hz; 400V ±10%, 30A version available
  • Load Regulation (full scale): <0.025%, DC to 100 Hz; <0.05%, 10 Hz to 10 kHz
  • Line Regulation (full scale): <0.1% for 10% line change
  • External Sense: Voltage-drop compensation sense line
  • Harmonic Distortion (80 kHz, low-passed): Less than 0.3% from 10 Hz to 30 kHz; 0.5% up to 50 kHz
  • Harmonic Distortion (30 kHz, low-passed): Less than 0.1% from 10 Hz to 50 kHz
  • DC Offset: <10 mV
  • Distortion: <0.2%
  • THD: .02% at 1kHz
  • Voltage Slew Rate: Load dependent; up to 80V per µs, typically 10 µs to 30 µs for 10% to 90% of full-scale change depending on load and power
  • Propagation Delay: 8 µsec
  • Efficiency: 85%, typical
  • Power Factor: .72, typical
  • Source Impedance: less than 70 mΩ + less than 10 µH
  • Cooling: Internal forced-air fans
  • Protection: Over/under voltage, over current, over temperature
  • Input, Signal In:
    • Unbalanced: BNC connector
    • Balanced: Terminal strip
  • Output: 3/8-inch high-current post connectors
 

Operating Environment

  • Temperature: 5 °C to 50 °C (41 °F to 122 °F);
    • Maximum output power derated above 30 °C (86 °F)
  • Humidity: Maximum relative humidity 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40 °C
  • Altitude: 3000 m Maximum
  • Environment: Indoor Use Only, Pollution degree 2
  • Equipment Class: Group 1 Class A
  • Transient Overvoltage: Overvoltage Category II
  • Dimensions (HxWxD): 35.05 x 22.56 x 31.56 inches (89.03 x 57.3 x 80.16 cm)
  • Weight (approx): 290 lbs. (131.5 kg)
PHOTOS
   

Controls, Indicators and Connectors

DOCUMENTS / DOWNLOADS
8500 Data Sheet 8500 Series Manual Configuration Settings Step File for Chassis

 

You may also like…

EMC Test Systems
We provide comprehensive solutions for power quality, conducted immunity, and induced susceptibility testing for the EMC industry.

High-Voltage Test Systems
Our high-voltage ripple test systems provide unparalleled accuracy and efficiency in assessing EV component immunity to ripple voltages.

Low-Voltage Test Systems
We provide comprehensive, single-box solutions for low-voltage standards testing for automotive, aerospace, industrial, and telecom industries.


Standards Waveform Generator
The 3110A is a simple-to-use yet powerful standards waveform generator, that can be combined with other AE Techron products to quickly create a wide range of EMC test solutions.