DC-50kHz, 40kW Switch-Mode Amplifier

8640

40 kW (up to 120 kVA), up to 320A continuous

Key Performance Capabilities:
  • Bandwidth: DC to 50 kHz
  • Voltage: 0 to 260 VRMS; 0 to 400 VDC
  • Slew rate: Up to 80 V/µs
  • Current: Up to 320 ARMS*
  • Distortion: <0.2%
  • Power: 40 kW*
  • Power levels up to 2X rated power when driving reactive loads
  • High power efficiency and density

*Models available with output power from 10 kW to 60 kW (capable of up to 120 kVA).

USA and TAA Compliant Logos

SKU: N/A Categories: ,
OVERVIEW

8640 amplifiers are 400Vp, low-noise, DC-to-50-kHz switch-mode amplifiers. They are fast enough for most DC automotive dropout testing and capable of AC voltages required for ISO 61000 and Aviation testing. Plus, they have low enough noise and distortion specifications to be the reference power source in power quality measurements. The 8640 amplifier is capable of reproducing AC, DC and AC+DC waveforms into loads from a dead short to high impedance. It can be used to simulate a battery at 13.5 VDC or be an AC source with a L-N potential of up to 260 VAC. Rated current, for a given voltage, is available for all waveform types (AC, DC or AC+DC) at frequencies from DC to 50 kHz. Voltages from 0 to 260 VRMS are available with no changes in configuration.

The 8640 excels when it comes to driving reactive loads. As frequencies increase, the effective impedance of the load becomes a much larger part of the total load to be driven (especially with inductive loads like coils). However, when driving reactive loads, the 8640 is capable of receiving, reprocessing and returning to the load up to 2X its rated power.

Configurable:

A key to everyday product usability is quick and easy product (re)configuration. The 8600 Series provides all key configuration controls on the back panel of the unit. Configuration options available include:

  • GAIN: Fixed or variable gain (0.16 to 40)
  • CURRENT LIMIT: From 5% to rated limit (to protect fragile DUTs or where specified in the Standard)
  • DC CONTROL: DC enabled or DC blocked and DC Servo (for driving transformer-coupled loads or coils)
  • INPUT: Balanced and/or unbalanced
  • MODE: Voltage source or current source
  • OUTPUT IMPEDANCE: Variable from 0 to 1 ohm (Voltage mode)
  • REMOTE SENSE: Correction to voltage drops between amplifier and the load
OUTPUT CHART

Output

CONTINUOUS AC OUTPUT CURRENT CONTINUOUS DC OUTPUT CURRENT*
VOLTS
RMS
8610 8620 8630 8640 8650 8660 VOLTS
DC
8610 8620 8630 8640 8650 8660
60 80A 160A 240A 320A 400A 480A 13.5-125 80A 160A 240A 320A 400A 480A
120 70A 140A 210A 280A 350A 420A 125-370* 10kW 20kW 30kW 40kW 50kW 60kW
230 35A 70A 105A 140A 175A 210A  

Note: 8610 power ratings shown are for unit configured for 240VAC. Performance data is for a purely resistive load; performance will be improved into loads that are partially or completely reactive.
* kW/V = A Limit

PERFORMANCE

SPECIFICATIONS

Performance Specifications

  • Operating Modes: AC, DC and AC + DC
  • Frequency, AC Mode Output (-3 dB): DC – 50 kHz
  • Max Voltage Ranges (no load):
    • AC: 0 – 260 VRMS
    • AC + DC: 0 – ±400 VP
  • Max Continuous Output Current: 320A RMS
  • Surge Rating: 2X power at up to 400Vp or 600A
  • Apparent Power Rating: Up to 2X continuous power rating at up to 400 Vp or 600A
  • Supply Voltage: Three-phase, 208V ±10% 120A, 50/60 Hz, 400VAC ±10%, 5-Wire 80A version available
  • Load Regulation (full scale): <0.025%, DC to 100 Hz; <0.05%, 10 Hz to 10 kHz
  • Line Regulation (full scale): <0.1% for 10% line change
  • External Sense: Voltage-drop compensation sense line
  • Harmonic Distortion (80 kHz, low-passed): Less than 0.3% from 10 Hz to 30 kHz; 0.5% up to 50 kHz
  • Harmonic Distortion (30 kHz, low-passed): Less than 0.1% from 10 Hz to 50 kHz
  • DC Offset: <10 mV
  • Distortion: <0.2%
  • THD: .02% at 1kHz
  • Voltage Slew Rate: Load dependent; up to 80V per µs, typically 10 µs to 30 µs for 10% to 90% of full-scale change depending on load and power
  • Propagation Delay: 8 µsec
  • Efficiency: 89%, typical
  • Power Factor: .92, typical
  • Source Impedance: less than 50 mΩ + less than 10 µH
  • Cooling: Internal forced-air fans
  • Protection: Over/under voltage, over current, over temperature
  • Input, Signal In:
    • Unbalanced: BNC connector
    • Balanced: Terminal strip
  • Output: 3/8-inch high-current post connectors
 

Operating Environment

  • Temperature: 5 °C to 50 °C (41 °F to 122 °F);
    • Maximum output power derated above 30 °C (86 °F)
  • Humidity: Maximum relative humidity 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40 °C
  • Altitude: 3000 m Maximum
  • Environment: Indoor Use Only, Pollution degree 2
  • Equipment Class: Group 1 Class A
  • Transient Overvoltage: Overvoltage Category II
  • Dimensions (HxWxD): 48.55 x 22.56 x 31.56 in (123.32 x 57.3 x 80.16 cm)
  • Weight (approx): 380 lbs. (172.4 kg)
PHOTOS
   

Controls, Indicators and Connectors

DOCUMENTS / DOWNLOADS
8600 Data Sheet   Configuration Settings  
8600 Series Datasheet    

 

 

You may also like…

EMC Test Systems
We provide comprehensive solutions for power quality, conducted immunity, and induced susceptibility testing for the EMC industry.

High-Voltage Test Systems
Our high-voltage ripple test systems provide unparalleled accuracy and efficiency in assessing EV component immunity to ripple voltages.

Low-Voltage Test Systems
We provide comprehensive, single-box solutions for low-voltage standards testing for automotive, aerospace, industrial, and telecom industries.


Standards Waveform Generator
The 3110A is a simple-to-use yet powerful standards waveform generator, that can be combined with other AE Techron products to quickly create a wide range of EMC test solutions.