Careers

Find a Sales Partner

Partner Portal

7224RLY

Up to 52 Ap Current Source

7224RLY

For Protection Relay Production Testing and Commissioning

  • High compliance voltage allows the 7224RLY to drive electromechanical relays directly
  • Maintains phase accuracy for any load from a dead short to 2 ohms
  • Front panel indicators for rapid assessment of amplifier status
  • Protection circuitry protects from input overloads, improper output connection (including shorted and improper loads), over-temperature, over-current, and supply voltages that are too high or low

Key Performance Capabilities:

  • Up to 50 Ap (35A RMS) output power at 0.5 ohms
  • Up to 158 Vp output voltage
  • Standard transconductance of 20 ±0.2% from short to 1-ohm load
  • Residual noise of less than 2.5 mA peak, from 40 Hz to 600 Hz

SKU: N/A Categories: ,
OVERVIEW

The 7224RLYwas created to meet the demanding requirements of the power utility industry. Capable of outputting a 40 mSec pulse with up to 52 amperes peak current, the 7224RLY is powerful enough to put protection relays, fuses and other critical components through a full range of tests.

The low noise floor, low distortion and minimal phase error of the 7224RLY make it the ideal amplifier for power grid modeling.

OUTPUT CHART

Pulse/Burst Specifications

Note: Testing performed in mid-level mode using 40 ms pulses with a 30% duty cycle.

TOTAL LOAD DURATION WAVEFORM OUTPUT POWER
1.0 ohms 5 minutes 60 Hz Sine 28A RMS / 40A peak
DC 20A peak
20 seconds 60 Hz Sine 30A RMS / 43A peak
DC 20A peak
0.2 seconds 60 Hz Sine 33A RMS / 47A peak
DC 30A peak
 

Accuracy

Amplitude vs Frequency at 1V input, 20A output,
amplifier transconductance set to 20
Load Input Signal Transconductance
1 kHz 100 Hz
2 ohms Sine 19.9 20
1 ohm Sine 20 20
o.5 homs Sine 20 20
Short* Sine 20 20

* Unimpeded wire.

PERFORMANCE

 

SPECIFICATIONS

Performance

  • Controlled-Current Bandwidth (0.25-ohm load): DC to 10 kHz
  • Maximum Output Current (0.5-ohm load): 35A RMS (50 Ap)
  • Maximum Output Voltage: 158 Vp
  • Maximum Output Power:: Dependent on load and frequency
  • Load Constraint for Maximum Output: 0.5 ohms + 200 mH (Note: all loads from 8-ohm to short are stable with 2 mH in series)
  • Output Offset Current: Less than 10.0 mA DC peak
  • Standard Transconductance (from short to 1-ohm load): 20 ±0.2%
  • Common Mode Rejection Ratio (40 to 600 Hz): -58 dB minimum
  • Unit-to-Unit Phase Error (60 Hz): ±0.1 degrees
  • Residual Noise (40 to 600 Hz): Less than 2.5 mA peak
  • Input-to-Output Phase Delay: -0.2 degrees
  • Out Accuracy: Less than ±1%

Input Characteristics

  • Balanced with ground: Three terminal barrier block connector, 20k ohm differential
  • Unbalanced: BNC connector, 10k ohm single ended
  • Max Input Voltage: ±10V, balanced or unbalanced
  • Common Mode Rejection: -58 dB with 5V input

Status Display, Control, I/O

  • Front Panel LED Displays indicate: Ready, Standby, Fault, Over Temp, Over Voltage, Overload
  • Soft Touch Switches for: Run, Stop, Reset
  • Gain Control, when enabled: Voltage gain adjustable from 20 to 0
  • On/Off Breaker
  • Back Panel Power Connection: 25 Amp IEC (with retention latch)
  • Signal Output: Three-position terminal strip (OUTPUT/COM/CHASSIS GROUND)
  • Signal Input: User-selectable BNC or barrier strip; balanced or unbalanced

Communication Capabilities

  • Current Monitor: 5A/V ± 1%; 2.5A/V ± 1% (differential configuration)
  • Reporting: System Fault, Over Temp, Over Voltage, Over Load
  • Remote Control via Interlock Connector: Force to Standby, Reset after a fault

Protection

  • Over/Under Voltage: ± 10% from specified supply voltage amplifier is forced to Standby
  • Over Current: Breaker protection on both main power and low voltage supplies
  • Over Temperature: Separate output transistor, heat sink, and transformer temperature monitoring and protection

Physical Characteristics

  • Chassis: The amplifier is designed for stand-alone or rack-mounted operation. The chassis is black aluminum with a powder coat finish. The unit occupies two EIA 19-inch-wide units.
  • Weight: 41 lbs (18.6 kg), Shipping: 51 lbs (23.2 kg)
  • AC Power: Single phase, 120 VAC, 60 Hz, 10 Amp service; (220-240 VAC, 50-60 Hz, 10 Amp service model available)
  • Operating Temperature: 10°C to 50°C (50°F to 122°F), maximum output Power de-rated above 30°C (86°F).
  • Humidity: 70% or less, non-condensing
  • Cooling: Forced air cooling from front to back through removable filters.
  • Airflow: 180CFM
  • Dimensions (HxWxD): 3.5” x 19” x 22.75” (8.9 cm x 48.3 cm x 57.8 cm)
PHOTOS

Controls, Indicators and Connectors

 

DOCUMENTS / DOWNLOADS
7224RLY Data Sheet 7224 Manual 7224RLY Manual Supplement SIM Interlock Connector Pinouts and Functions Configuration Settings Step File for Chassis