T 1000: Ten-to-One Step-Down, Up to 100 ARMS Secondary Current

T1000

The T1000 Magnetic-Field Susceptibility Transformer was designed to exceed the AF Magnetic Field susceptibility test requirements of DO 160 Section 19 and Boeing D6-16050 Section 7.2. It may also be used as a 10-to-1 step-down transformer for output current of up to 100ARMS.

The T1000 transformer provides up to 300A-m and is able to generate up to 100ARMS. The turns ratio provides a ten-to-one step down to the secondary winding.

The T1000 provides convenient input connectors via binding posts. Standard 0.75-inch spacing of binding posts allows use of standard plugs. Output is via Multi Contact 125A plugs.

A 12-amp circuit breaker protects the unit against over-current conditions. A rugged, impact-resistant case and robust design protects the transformer from accidental damage.

The T1000 transformer is for use by experienced staff.

T 1000

Magnetic Field Susceptibility Transformer

  • For testing to DO 160 Section 19 and Boeing D6-16050-5 Section 7.2 standards
  • Optimized for use with AE Techron 7220 Series amplifiers
  • Protected from over-current by 12A circuit breaker
  • Durable steel and high-density polyethylene case for impact resistance

Key Performance Capabilities:

  • Up to 100 ARMS secondary current
  • Provides up to 300 A-m
  • Ten-to-one step-down
  • Output via feed-through terminal block connectors (150A); accepts up to AWG 1/0 wire

Performance

T 1000 Maximum SOA (Safe Operating Area)

T 1000 Safe Operating Area

Specifications

Technical

Primary: 200 Vp maximum input
Secondary: 20.0 Vp maximum output
Dielectric Test: 1200 VDC
Turns Ratio: Ten-to-one step down
Protection: Input power-protected via circuit breaker

Controls and Connectors

Input Terminals: 4-way binding posts
Output Terminals: Feed-through terminal block connectors (150A); accepts up to AWG 1/0 wire
Circuit Breaker: Primary input limited to 12A; push to reset

Physical Characteristics

Case: Steel interior shell with a durable external shell made from high-density polyethylene for impact resistance.
Operating Conditions,
   Temperature:
10°C to 40°C (50°F to 104°F)
   Humidity: 70% or less, non-condensing
Recommended Ambient Temperature: 27°C (77°F)
Cooling: Natural air convection
Weight: 15 lbs. (6.8 kg)
Dimensions (WxDxH): 5.25 in. x 10.375 in. x 9.75 in. (13.3 cm x 26.4 cm x 24.8 cm)

Application

DO 160 Section 19 Testing

T 1000 Application

Standards

Meets or exceeds the performance requirements for testing to these Specifications:

  • DO 160 Section 19

Front & Back

T 1000 front and back

Downloads

T 1000 Datasheet

T 1000 Datasheet

Complete technical specifications

T 1000 Instruction Sheet

T 1000 Instruction Sheet

Includes full specifications plus setup and maintenance instructions

T 1000 Declaration of Conformity

T 1000 Declaration of Conformity

For EU countries

You might also be interested in:

Recommended Products

7224

7224

DC-enabled AC Amplifier

AC Power at 20 kHz: 900 Wrms
For High-Power Applications to: 100 kHz

7234

7234

DC-enabled AC Amplifier

AC Power at 20 kHz: 900 Wrms
For High-Power Applications to: 150+ kHz

GCL

GCL

Ground Current Limiter

Active protection with red LED indicator; resettable

 

VMON20

VMON20

Voltage & Current Monitor

Convenient, scaled monitoring of voltage and current

Related Products

T 2000

T 2000

Coupling Transformer

Turns Ratio: 2-to-1 step down
Audio Power: 200 watts MAX

T 3700

T 3700

Coupling Transformer

Turns Ratio: 1-to-37 step up
Output: Up to 3700 Vrms

Want to discuss a product or application?

Your local AE Techron Representative can help find the right system for your needs.
We're the audio-bandwidth experts.

Find Local Rep