ACCESSORIES

Solutions for Multi-Amp, MRI and Custom Uses

SIM-BNC-OPTOC

Current Probe

The SIM-BNC-OPTOC Specialized Input Module allows multiple 7000-Series amplifiers to be configured as a series output system to increase the available output voltage to the load. The SIM-BNC-OPTOC kit also includes a BNC connector safety cover.

The SIM-BNC-OPTOC module is required for all Series configurations and should be used in conjunction with the DB9M CABLE (see below).

[VIEW AE TECHRON MULTI-AMP CONFIGURATION GUIDE (4M pdf format)]

DB9M CABLE

Current Probe

The DB9M (OPTOC) CABLE is a high-voltage Interlock cable that provides superior insulation for multi-amp series systems running high-voltage applications.

The DB9M CABLE is required for all Series configurations and should be used in conjunction with the SIM-BNC-OPTOC module (see above).

[VIEW AE TECHRON MULTI-AMP CONFIGURATION GUIDE (4M pdf format)]

BAL RES KIT

Current Probe

Three types available: 7224 BAL RES KIT, 7548 BAL RES KIT and 7796 BAL RES KIT. Ballast resistors are required for all Parallel configurations. The ballast resistor kits include one ballast resistor (two in the 7796 kit) with connection terminals and mounting hardware. The 7224 BAL RES KIT also contains the shunt required to defeat the amplifier's external level control.

NOTE: AE Techron Ballast Resistor Kits are sold as parts kits only. Buyers are responsible for installing the Ballast Resistor Kit in a way that meets local Safety requirements.

Alternatively, ballast resistor installation, which will meet generic safety requirements, can be ordered from AE Techron at the time of purchase or is available through AE Techron Service.

[VIEW AE TECHRON MULTI-AMP CONFIGURATION GUIDE (4M pdf format)]

PARALLEL WIRING KIT

Current Probe

Six types available: 7224 2-AMP, 7548/7796 2-AMP, 7224 3-AMP, 7548/7796 3-AMP, 7224 4-AMP and 7548/7796 4-AMP. Parallel wiring kits include the DB-25 Interlock cable for system communication and the output wiring for connecting system amplifiers to the load. The kits also include the wire(s) required for wiring the parallel inputs through the Removable Barrier Block (WECO) connectors. Parallel wiring kits are recommended for all Parallel configurations

[VIEW AE TECHRON MULTI-AMP CONFIGURATION GUIDE (4M pdf format)]

 

 

BNC PARALLEL INPUT KIT

Current Probe

Optional kit for wiring parallel inputs through the BNC input connectors instead of the default Removable Barrier Block connectors. Each kit contains one BNC patch cable and one BNC T-connector. NOTE: Now included in parallel wiring kits.

[VIEW AE TECHRON MULTI-AMP CONFIGURATION GUIDE (4M pdf format)]

 

 

MTL1: MRI TEST LOAD

MTL1-MRI Test LoadThe MTL1 is a 1.2 kW resistive test load design for the testing of power amplifiers used in MRI systems. It provides a load of a 0.5-ohm 1.2-kW resistor in series with a 100 microHenry coil.

[VIEW INSTRUCTION SHEET (pdf format)]

 

 

GCL: GROUND CURRENT LIMITER

GCL - Ground Current LimiterAE Techron’s GCL provides active protection against excessive ground current. It is superior to the factory-default ground-current protection on many AE Techron amplifiers (a 2.7-ohm resistor between the amplifier’s Chassis Ground and COM or Sampled Common output terminals) because it places the amplifier in Standby, provides a visual indication that a fault has occurred, and can be easily reset.

[VIEW INSTRUCTION SHEET (pdf format)]

 

 

VMON20: VOLTAGE AND CURRENT MONITOR

VMON20 - Voltage and Current MonitorAE Techron’s VMON20 provides a fast and convenient connection for scaled monitoring of voltage and current output on AE Techron 7000-Series amplifiers. The VMON20 attaches to the amplifier via the DB-25 Interlock connector located on the amplifier’s back-panel SIM input card. It provides scaled voltage output to monitor the amplifier output voltage (20V to 1V). The VMON20 also provides easy access to the amplifier’s internal scaled 20A to 1V current monitor (5A to 1V on 7212 and 7224 amplifiers).

[VIEW INSTRUCTION SHEET (pdf format)]