Electromagnetic Compatibility Testing

T1000 Transformer T1000 MAGNETIC FIELD SUSCEPTIBILITY TRANSFORMER
for DO 160 Section 19 and
BOEING D6-16050-5 Section 7.2

The T1000 Magnetic-Field Susceptibility Transformer was designed to exceed the AF Magnetic Field susceptibility test requirements of DO 160 Section 19 and Boeing D6-16050 Section 7.2. It may also be used as a 10-to-1 step-down transformer for output current of up to 100ARMS.

The T1000 transformer provides up to 300A-m and is able to generate up to 100ARMS. The turns ratio provides a ten-to-one step down to the secondary winding.

The T1000 provides convenient input connectors via binding posts. Standard 0.75-inch spacing of binding posts allows use of standard plugs. Output is via Multi Contact 125A plugs.

A 12-amp circuit breaker protects the unit against over-current conditions. A rugged, impact-resistant case and robust design protects the transformer from accidental damage.

The T1000 transformer is for use by experienced staff.

 

  • PERFORMANCE
  • FEATURES
  • APPLICATION
  • STANDARDS
  • SPECIFICATIONS

PERFORMANCE

T1000 Safe Operating Area

T1000 Maximum SOA (Safe Operating Area)

FEATURES

  • Up to 100ARMS secondary current.
  • Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5 Section 7.2.
  • Circuit breaker protected from over-current.
  • Durable steel and high-density polyethylene case for impact resistance.

APPLICATION

DO 160 Section 19 Magnetic Test Load Wiring

STANDARDS

Meets or exceeds the performance requirements for testing to these Specifications:

  • Do 160 Section 19
  • Boeing D6-16050-5 Section 7.2

SPECIFICATIONS

Technical

Primary: 200VP maximum input

Secondary: 20.0VP maximum output

Dielectric Test: 1200VDC

Turns Ratio: Ten-to-one step down

Protection: Input power-protected via circuit breaker

Controls and Connectors

Input Terminals: 4-way binding posts

Output Terminals: Multi Contact 125A plugs

Circuit Breaker: Primary input limited to 12A; push to reset

Physical Characteristics

Case: Steel interior shell with a durable external shell made from high-density polyethylene for impact resistance.

Operating Conditions,
   Temperature:
10°C to 40°C (50°F to 104°F)
   Humidity: 70% or less, non-condensing

Recommended Ambient Temperature: 27°C (77°F)

Cooling: Natural air convection

Weight: 15 lbs. (6.8 kg)

Dimensions (WxDxH): 5.25 in. x 10.375 in. x 9.75 in. (13.3 cm x 26.4 cm x 24.8 cm)